Section 07220
PART 1 GENERAL
1.01 SUMMARY
Specifier Note: Select roof system type and requirements. Coordinate with other sections.
A. Section includes: Roofing recovery boards for use in the following roof systems:
1. Roof System Type (select desired roof system):
a. Loose-Laid, Ballasted
b. Mechanically Attached
B. Related Sections:
1. Section 07500 - Membrane Roofing
2. Section 07530 - Elastomeric Sheet Roofing
3. Section 07700 - Roof Specialties and Accessories
4. Section 07722 - Roof Hatches
1.02 REFERENCES
A. American Society for Testing and Materials (ASTM):
1. ASTM C 272 - Test Method for Water Absorption of Core Materials for Structural Sandwich
Constructions
2. ASTM C 303 - Test Method for Density of Preformed Block-Type Thermal Insulation
3. ASTM C 518 - Test Method for Steady-State Heat Flux Measurements and Thermal Transmission
Properties by Means of the Heat Flow Meter Apparatus
4. ASTM D 1621 - Test Method for Compressive Properties of Rigid Cellular Plastics
5. ASTM E 84/UL 723 - Test Method for Surface Burning Characteristics of Building Materials
6. ASTM E 96 - Test Methods for Water Vapor Transmission of Materials
1.03 SUBMITTALS
A. General: Submittals shall be in accordance with Division 1 section on “Submittal Procedures”.
GreenGuard
®
Roofing Recovery
Board
Old Built-up Roof
Existing Insulation
Non-combustible Deck
(Concrete)
Mechanically Attached EPDM
(Light-colored or dark)
GreenGuard
®
Roofing Recovery Boards
Installation Guide
Mechanically-Fastened and Loose-Laid / Ballasted Roof Systems
Mechanically Attached EPDM
(Light-colored or dark)
GreenGuard
®
Roofing Recovery
Board
Existing Insulation
Non-combustible Deck
(Steel or Concrete)
Old Built-up Roof
Przeglądanie stron 0
1 2 3 4 5 6

Podsumowanie treści

Strona 1 - Roofing Recovery Boards

1-800-241-4402 www.TrustGreenGuard.comSection 07220PART 1 GENERAL1.01 SUMMARYSpecifier Note: Select roof system type and requirements. Coordinate w

Strona 2 - PART 2 PRODUCTS

B. Product Data: Submit roofing recovery board specifications.C. Quality Assurance: Submit the following:1. Compliance Reports: See ICC-ES Evaluatio

Strona 3 - PART 3 EXECUTION

c. Thermal Resistance (at 75°F mean temperature): ASTM C 518; 1.5 ft2•hr•°F/Btu (0.26 m2(k/W).Specimens are tested in accordance with the FTC “R-val

Strona 4

3.04 INSTALLATIONA. General:1. Install only as much roofing recovery board as can be covered by the roofing materials in the same day2. GreenGuard®PB

Strona 5

Fastening Patterns for GreenGuard®Roofing Recovery Boards Used UnderLight-Colored Roof MembranesFastening Patterns for GreenGuard®Roofing Recovery Boa

Strona 6 - APPROVED

1-800-241-4402 www.TrustGreenGuard.comINSTL-PB63/14WARNING: Foam insulation will ignite if exposed to fire of sufficient heat and intensity. Protect f